Small Concrete Pump for Concrete Delivery

line pump
line pump
concrete pourer
concrete pourer

A concrete pump needs to match the required delivery height, pipe route, concrete mix, and site conditions. YG offers six small concrete pump models with different output, pumping distance, aggregate capacity, motor power, and machine dimensions.

For model selection, check the vertical and horizontal delivery distance first. Then confirm aggregate size, concrete slump, pipe diameter, required output, power supply, and available installation space.

Get a Free Quote

Models and Technical Parameters of Small Concrete Pump

The six models cover different concrete delivery requirements. Compare their main specifications before choosing the equipment.

Parameter102030405060
Motor Power15 kW/25 hp22 kW / Diesel 410237 kW / Diesel 410545 kW / Diesel 410855 kW / Diesel 610290 kW
Output8–10 m³/h8–12 m³/h13–15 m³/h20–25 m³/h30–35 m³/h55–60 m³/h
Pressure10 MPa15 MPa20 MPa23 MPa23 MPa23 MPa
Max Aggregate0–3 cm0–2 cm0–3 cm0–4 cm0–4 cm0–5 cm
Vertical20–30 m40–50 m20–60 m30–130 m30–150 m30–150 m
Horizontal50–80 m80–100 m50–150 m50–350 m50–500 m50–500 m
Pipe Diameter80–100 mm80–100 mm80–125 mm80–125 mm80–125 mm125 mm
Weight600 kg900 kg1600 kg2200 kg2200 kg3500 kg
Dimensions2100×890×13303200×1480×16003800×1600×18003880×1650×16804300×1600×18004300×1600×1800

Output ranges from 8–10 m³/h for YG-10 to 55–60 m³/h for YG-60. Actual output depends on the concrete mix, pipe route, conveying distance, bends, and site conditions.

Get a Free Quote

How to Choose a Small Concrete Pump by Distance

concrete trailer pump for sale
concrete trailer pump for sale

The listed vertical delivery ranges are 20–30 m to 30–150 m, while horizontal ranges reach 50–500 m.

  • YG-10: 20–30 m vertical / 50–80 m horizontal
  • YG-20: 40–50 m vertical / 80–100 m horizontal
  • YG-30: 20–60 m vertical / 50–150 m horizontal
  • YG-40: 30–130 m vertical / 50–350 m horizontal
  • YG-50: 30–150 m vertical / 50–500 m horizontal
  • YG-60: 30–150 m vertical / 50–500 m horizontal

Measure the actual pipe route from the pump to the discharge point, including both horizontal and vertical sections. The number of elbows also affects flow resistance, so a complete pipe layout is useful for long-distance projects.

Get a Free Quote

Aggregate Size and Concrete Slump

The maximum listed aggregate sizes range from 0–2 cm to 0–5 cm. For example, YG-20 handles up to 0–2 cm, while YG-60 supports up to 0–5 cm.

Concrete slump should also be checked before selecting a mini concrete pump. Provide:

  • Maximum aggregate size
  • Concrete slump
  • Required output
  • Mix information
  • Pipe diameter

The pump should match the actual concrete mix rather than output alone.

Get a Free Quote

Pipe Diameter and Delivery Route

cement pumping machine
cement pumping machine

The listed pipe diameters range from 80 mm to 125 mm. YG-10 and YG-20 use 80–100 mm pipes, while YG-30 to YG-50 support 80–125 mm configurations. YG-60 uses a 125 mm pipe.

Pipe diameter should match the concrete mix, aggregate size, pump configuration, and delivery route. When requesting a configuration, provide the pipe diameter, horizontal length, vertical length, number of elbows, and discharge location.

Get a Free Quote

Power Supply and Machine Dimensions

Motor powers range from 15 kW to 90 kW. The YG-20, YG-30, YG-40, and YG-50 use diesel engines according to the supplied specifications.

Machine weight ranges from 600 kg to 3500 kg. YG-10 measures 2100 × 890 × 1330 mm, while YG-50 and YG-60 measure 4300 × 1600 × 1800 mm.

For restricted sites, check the entrance width, transport route, installation area, and available working space before ordering.

Get a Free Quote

Small Concrete Pump for Different Construction Sites

concrete trailer pump
concrete trailer pump

Small residential projects: YG-10 and YG-20 provide lower output and shorter conveying ranges.

Medium construction work: YG-30 and YG-40 offer higher output and longer delivery distances for foundation, floor, and structural concrete work.

Long-distance delivery: YG-50 and YG-60 reach up to 500 m horizontally and 150 m vertically. YG-60 provides up to 55–60 m³/h output.

Restricted construction areas: YG-10 weighs 600 kg and has compact dimensions of 2100 × 890 × 1330 mm.

Get a Free Quote

Application in Cebu City

A residential construction project in Cebu City, Philippines, requires concrete delivery to an elevated pouring location. The planned route includes 120 m of vertical conveying distance and up to 260 m of horizontal conveying distance, with aggregate up to 30 mm.

The YG-40 matches these listed requirements:

  • Vertical conveying distance: up to 130 m
  • Horizontal conveying distance: up to 350 m
  • Maximum aggregate size: 0–4 cm
  • Motor power: 45 kW / Diesel 4108
  • Output: 20–25 m³/h
  • Pressure: 23 MPa

The project should also confirm concrete slump, pipe diameter, number of elbows, power or diesel requirements, and installation space before final configuration.

Get a Free Quote

Confirm Before Ordering

portable concrete pump
portable concrete pump
  1. Required output
  2. Vertical conveying distance
  3. Horizontal conveying distance
  4. Pipe layout
  5. Number of elbows
  6. Maximum aggregate size
  7. Concrete slump
  8. Pipe diameter
  9. Power or diesel requirements
  10. Installation and transport space

Get a Free Quote

YG Small Concrete Pump Options

YG offers small concrete pumps for residential construction, foundation work, floor casting, road projects, and other concrete pumping applications. The product range includes small concrete pumps, mini concrete pumps, portable concrete mixers with pumps, and trailer concrete pumps, with different output capacities, pumping distances, and power options.

Get a Free Quote

FAQ

Does the listed output equal actual pumping output?

No. The listed output is the rated range. Actual output can vary with the concrete mix, pipe route, conveying distance, bends, and operating conditions.

Why does the number of elbows matter?

Elbows change the direction of concrete flow and increase resistance. Their number and position should be included when checking the pump configuration.

Can motor power alone determine the model?

No. Delivery distance, aggregate size, concrete mix, pipe layout, required output, power source, and site space also affect model selection.

What should I provide for a complex pipe route?

Provide the horizontal and vertical pipe lengths, pipe diameter, number of elbows, and discharge location. A simple pipe layout can also help with configuration.

    Please feel free to give your inquiry in the form below. We will reply in 24 hours.

    Product Model:

    Your Name(required):

    Your Email(required):

    Your Phone(required):

    Your country:

    Your Whatsapp(required):

    Your Message(required):

    Scroll to Top